Power Quality Analyzer

PITE3561 Power Quality Analyzer is Smart measurement and analysis for 3-phase/4-wire system, Compatible with EN50160 and testing frequency up to 1000Hz

 Why PITE?

An Easy-to-use power quality tools is a ”must-have” for any person who maintains or troubleshoots three phase power. PITE three-phase power quality meters help you locate, predict, prevent and troubleshoot problems in power distribution systems. We offer a full range of trouble-shooters for the prevention and analyzing of the power quality problem. It is not only your problem solver, but also money saver.

DOWNLOAD

Optional Current Clamps:

Features

Portable design and colorful touch screen
Applied to standard of EN 50160
Could test 3-phase volt, null line volt, 3-phase current, null line current, etc.
Up to 50 times harmonic testing with frequency spectrum graph
Power testing: 3-phase apparent power, active power, reactive power, power factor, and 3-phase electric power.
3-phase unbalance testing with vivid chart
Record at least 40 times of surge current
Testing for wave motion, short-time flicker and long-time flicker
Record up to 40 times of sag and swell
Could have long-time record for basic (stable) power quality parameter. Recording time interval adjustable between 1 second and 30 minutes.
Digital oscilloscope, checking waveform for voltage and current signal
With PITE Data View software for convenient analyzing of testing result

Technical Parameter

LCD: 7” 320 x 240 TFT touch screen
Input Impedance: >2MΩ,20pF
Measurement Range: Vrms 10~1000V
Current: 5A, 10A, 100A, 1000A, 1500A and 3000A (with customized current clamps)
Frequency: 30Hz~1000Hz
Harmonic Measurement: 1~50th
Inrush Current: 2000A
Peak Voltage: 1000V
Internal Memory: 16MB
External Memory:4GB
Communication Port: USB
W.(main unit): 1.2 kg
Battery: 14.4V 2000mAh Durable for 5 hours after full charge

Accuracy, resolution and range

Measurement range Resolution Accuracy
Volt/Amps/Hertz
Vrms (ac+dc) 1 Vrms to 10 Vrms
10 Vrms to 100 Vrms
100 Vrms to 700 Vrms
0.001 Vrms
0.01 Vrms
0.1 Vrms
± 0.2 % of nominal voltage
Vpk 1 Vpk to 700 Vpk 0.001 Vrms
0.01 Vrms
0.1 Vrms
5 % of nominal voltage
Voltage Crest Factor (CF) 1.0 to > 10 0.01 ± 5 %
Arms (ac+dc) 0 Arms to 10Arms
10 Arms to 100Arms
1000 Arms to 1000Arms
1000 Arms to 3000Arms
0.001 Arms
0.01 Arms
0.1 Arms
1 Arms
± 0.5 % ± 5 counts3
Apk 1Apk to 3000 Apk 1 A ± 5 %
A Crest Factor (CF) 1 to 10 0.01 ± 5 %
Hz 30 Hz to70 Hz 0.01 Hz ± 0.01 Hz
Dips and swells
Vrms½ (ac+dc) 0.0 % to 200 % of nominal voltage 0.1 Vrms ± 1 % of nominal voltage
Arms½ (ac+dc) 0 Arms to 10Arms
10 Arms to 100Arms
1000 Arms to 1000Arms
1000 Arms to 3000Arms
0.001 Arms
0.01 Arms
0.1 Arms
1 Arms
± 1 % ± 10 counts3
Threshold levels Programmable thresholds in percent of nominal voltage
Event detection based upon ½ cycle rms voltages
Captures dips, swells, interruptions and rapid voltage changes
Duration hhh,mm,ss,mmm Half cycle One cycle

Accuracy, resolution and range cont.

Measurement range Resolution Accuracy
Harmonics
Harmonic order (n) DC, 1 to 50 grouping: harmonic groups according to IEC 61000-4-7
Inter-Harmonic order Off, 1 to 49 grouping: harmonic and interharmonic subgroups according to IEC 61000-4-7
Vrms        Relative (%f):
Absolute:
0.0 % to 100.0 %
0.0 Vrms to 700 Vrms
0.1 %
0.1 Vrms
± 0.1 % ± n x 0.1 % (± 0.4 % for %r)
± 0.05 % of nominal voltage if
< 1 % of nominal voltage
± 5 % if ≥ 1 % of nominal voltage
Arms       Relative (%f):
Absolute:
0.0 % to 100.0 %
0 Arms to 10Arms
10 Arms to 100Arms
1000 Arms to 1000Arms
1000 Arms to 3000Arms
0.1 %
0.001 Arms
0.01 Arms
0.1 Arms
1 Arms
± 0.1 % ± n x 0.1 % (± 0.4 % for %r)
± 5 % ± 5 counts
THD(n=40)(relative %f or %r) 0.0 % to 100.0 % 0.1% ± 2.5 % V and A (± 5 % Watt)
Hz 0 Hz to 3000 Hz 1 Hz ± 1 Hz
Power and energy
Watt (VA, VAR) 1.0 MW to 20.00 MW 0.1 kW to 1 kW1 ± 0.5 % ± 10 counts3
kWh6 (kVA6, kVAR6) 00.00 kWhr to 200.0 GWhr1 0.01 Xhr to 100 Whr ± 0.5 % ± 10 counts3
Power Factor 0 to 1 0.001
0.001
± 0.005
Cos φ/DPF 0 to 1 ± 0.005
Flicker
Pst (1min), Pst, Plt, PF5 instantenous
Flicker
0.00 to 20.00 0.01 Within ± 5 % of tabulated values according IEC61000-4-15
Unbalance
Volts (neg. and zero seq.) 0.0 % to 5.0 % 0.1% ± 0.15 %
Current (neg. and zero seq.) 0.0 % to 20 % 0.1% ± 1 %
Phase angle        volts
current
-360.0 ° to 0.0 °
-360.0 ° to 0.0 °
0.1 º
0.1 º
± 2 counts
± 5 counts3
Transient capture
Inrush mode
Arms (ac+dc) 0.0kArms to 3k Arms 0.001 Arms to 10 Arms ± 1 % of meas ± 5 counts
Inrush Duration mm:ss:mmm between 7.5 s to 30 minutes selectable 10 ms ± 20 ms (Fnominal = 50 Hz)

Trend recording

Method AutoTrend automatically records min, max and average values over time for all readings being displayed for the 3 phases and neutral simultaneously
Volts/Amps/Hertz, Harmonics, Power and Energy, Flicker, Unbalance and Mains Signaling4 mode
Sampling 5 readings/sec continuous sampling per channel
Recording time From 30 min with 1 second display resolution up to 450 days with 6 hour display resolution.
Memory 16MB internal + 4GB external
Dips and Swells mode
Sampling 100/120 readings/sec continuous sampling per channel
Recording time From 90 sec with 25 msec display resolution up to 450 days with 3 hr display resolution
Memory 16MB internal + 4GB external
Inrush currents and flicker PF5 mode
Sampling 100/120 readings/sec continuous sampling per channel
Recording time From 7.5 sec with 25 msec display resolution up to 30 min with 500 msec display resolution for Inrush measurements and up to 2 hr with 2.5 sec display resolution for PF5 recordings
Memory 16MB internal + 4GB external
Logger mode
Sampling Combination of 5 readings/sec and 100/1202 readings/sec continuous sampling per channel depending on the parameter measured
Recording time Depends on selected readings and averaging time
Memory 16MB internal + 4GB external
Monitor mode
Sampling Combination of 5 readings/sec and 100/120 readings/sec continuous sampling per channel depending on the parameter measured
Recording time Up to 1 week with 10 min resoluto
Memory 16MB internal + 4GB external
Limits According EN50160 or customer definable

Measurement method

Vrms, Arms 10/12 cycle contiguous non overlapping intervals using 500/416 samples per cycle in accordance with IEC 61000-4-30
Vpeak, Apeak Absolute highest sample value within 10/12 cycle interval with 40 μs sample resolution
V Crest Factor Measures ratio between the Vpeak and Vrms
A Crest Factor Measures ratio between the Apeak and Arms
Hz Measured every 10 sec in accordance with IEC61000-4-30
Vrms½, Arms½ Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle.
This technique is independent for each channel in accordance with IEC 61000-4-30.
Harmonics Calculated from 10/12-cycle gapless harmonic group measurements on Voltage and Amps according to IEC 61000-4-7
Watt Selectable Total or Fundamental real power display
Calculates average value of instantaneous power over 10/12 cycle period for each phase
Total Active Power PT = P1 + P2 + P3