PITE 3561
PITE3561 Power Quality Analyzer is Smart measurement and analysis for 3-phase/4-wire system, Compatible with EN50160 and testing frequency up to 1000Hz
Why PITE?
An Easy-to-use power quality tools is a ”must-have” for any person who maintains or troubleshoots three phase power. PITE three-phase power quality meters help you locate, predict, prevent and troubleshoot problems in power distribution systems. We offer a full range of trouble-shooters for the prevention and analyzing of the power quality problem. It is not only your problem solver, but also money saver.
Optional Current Clamps:
Features
Portable design and colorful touch screen
Applied to standard of EN 50160
Could test 3-phase volt, null line volt, 3-phase current, null line current, etc.
Up to 50 times harmonic testing with frequency spectrum graph
Power testing: 3-phase apparent power, active power, reactive power, power factor, and 3-phase electric power.
3-phase unbalance testing with vivid chart
Record at least 40 times of surge current
Testing for wave motion, short-time flicker and long-time flicker
Record up to 40 times of sag and swell
Could have long-time record for basic (stable) power quality parameter. Recording time interval adjustable between 1 second and 30 minutes.
Digital oscilloscope, checking waveform for voltage and current signal
With PITE Data View software for convenient analyzing of testing result
Technical Parameter
LCD: 7” 320 x 240 TFT touch screen
Input Impedance: >2MΩ,20pF
Measurement Range: Vrms 10~1000V
Current: 5A, 10A, 100A, 1000A, 1500A and 3000A (with customized current clamps)
Frequency: 30Hz~1000Hz
Harmonic Measurement: 1~50th
Inrush Current: 2000A
Peak Voltage: 1000V
Internal Memory: 16MB
External Memory:4GB
Communication Port: USB
W.(main unit): 1.2 kg
Battery: 14.4V 2000mAh Durable for 5 hours after full charge
Accuracy, resolution and range
Measurement range | Resolution | Accuracy | |
Volt/Amps/Hertz | |||
Vrms (ac+dc) | 1 Vrms to 10 Vrms 10 Vrms to 100 Vrms 100 Vrms to 700 Vrms |
0.001 Vrms 0.01 Vrms 0.1 Vrms |
± 0.2 % of nominal voltage |
Vpk | 1 Vpk to 700 Vpk | 0.001 Vrms 0.01 Vrms 0.1 Vrms |
5 % of nominal voltage |
Voltage Crest Factor (CF) | 1.0 to > 10 | 0.01 | ± 5 % |
Arms (ac+dc) | 0 Arms to 10Arms 10 Arms to 100Arms 1000 Arms to 1000Arms 1000 Arms to 3000Arms |
0.001 Arms 0.01 Arms 0.1 Arms 1 Arms |
± 0.5 % ± 5 counts3 |
Apk | 1Apk to 3000 Apk | 1 A | ± 5 % |
A Crest Factor (CF) | 1 to 10 | 0.01 | ± 5 % |
Hz | 30 Hz to70 Hz | 0.01 Hz | ± 0.01 Hz |
Dips and swells | |||
Vrms½ (ac+dc) | 0.0 % to 200 % of nominal voltage | 0.1 Vrms | ± 1 % of nominal voltage |
Arms½ (ac+dc) | 0 Arms to 10Arms 10 Arms to 100Arms 1000 Arms to 1000Arms 1000 Arms to 3000Arms |
0.001 Arms 0.01 Arms 0.1 Arms 1 Arms |
± 1 % ± 10 counts3 |
Threshold levels | Programmable thresholds in percent of nominal voltage Event detection based upon ½ cycle rms voltages Captures dips, swells, interruptions and rapid voltage changes |
||
Duration | hhh,mm,ss,mmm | Half cycle | One cycle |
Accuracy, resolution and range cont.
Measurement range | Resolution | Accuracy | |
Harmonics | |||
Harmonic order (n) | DC, 1 to 50 grouping: harmonic groups according to IEC 61000-4-7 | ||
Inter-Harmonic order | Off, 1 to 49 grouping: harmonic and interharmonic subgroups according to IEC 61000-4-7 | ||
Vrms Relative (%f): Absolute: |
0.0 % to 100.0 % 0.0 Vrms to 700 Vrms |
0.1 % 0.1 Vrms |
± 0.1 % ± n x 0.1 % (± 0.4 % for %r) ± 0.05 % of nominal voltage if < 1 % of nominal voltage ± 5 % if ≥ 1 % of nominal voltage |
Arms Relative (%f): Absolute: |
0.0 % to 100.0 % 0 Arms to 10Arms 10 Arms to 100Arms 1000 Arms to 1000Arms 1000 Arms to 3000Arms |
0.1 % 0.001 Arms 0.01 Arms 0.1 Arms 1 Arms |
± 0.1 % ± n x 0.1 % (± 0.4 % for %r) ± 5 % ± 5 counts |
THD(n=40)(relative %f or %r) | 0.0 % to 100.0 % | 0.1% | ± 2.5 % V and A (± 5 % Watt) |
Hz | 0 Hz to 3000 Hz | 1 Hz | ± 1 Hz |
Power and energy | |||
Watt (VA, VAR) | 1.0 MW to 20.00 MW | 0.1 kW to 1 kW1 | ± 0.5 % ± 10 counts3 |
kWh6 (kVA6, kVAR6) | 00.00 kWhr to 200.0 GWhr1 | 0.01 Xhr to 100 Whr | ± 0.5 % ± 10 counts3 |
Power Factor | 0 to 1 | 0.001 0.001 |
± 0.005 |
Cos φ/DPF | 0 to 1 | ± 0.005 | |
Flicker | |||
Pst (1min), Pst, Plt, PF5 instantenous Flicker |
0.00 to 20.00 | 0.01 | Within ± 5 % of tabulated values according IEC61000-4-15 |
Unbalance | |||
Volts (neg. and zero seq.) | 0.0 % to 5.0 % | 0.1% | ± 0.15 % |
Current (neg. and zero seq.) | 0.0 % to 20 % | 0.1% | ± 1 % |
Phase angle volts current |
-360.0 ° to 0.0 ° -360.0 ° to 0.0 ° |
0.1 º 0.1 º |
± 2 counts ± 5 counts3 |
Transient capture | |||
Inrush mode | |||
Arms (ac+dc) | 0.0kArms to 3k Arms | 0.001 Arms to 10 Arms | ± 1 % of meas ± 5 counts |
Inrush Duration | mm:ss:mmm between 7.5 s to 30 minutes selectable | 10 ms | ± 20 ms (Fnominal = 50 Hz) |
Trend recording
Method | AutoTrend automatically records min, max and average values over time for all readings being displayed for the 3 phases and neutral simultaneously |
Volts/Amps/Hertz, Harmonics, Power and Energy, Flicker, Unbalance and Mains Signaling4 mode | |
Sampling | 5 readings/sec continuous sampling per channel |
Recording time | From 30 min with 1 second display resolution up to 450 days with 6 hour display resolution. |
Memory | 16MB internal + 4GB external |
Dips and Swells mode | |
Sampling | 100/120 readings/sec continuous sampling per channel |
Recording time | From 90 sec with 25 msec display resolution up to 450 days with 3 hr display resolution |
Memory | 16MB internal + 4GB external |
Inrush currents and flicker PF5 mode | |
Sampling | 100/120 readings/sec continuous sampling per channel |
Recording time | From 7.5 sec with 25 msec display resolution up to 30 min with 500 msec display resolution for Inrush measurements and up to 2 hr with 2.5 sec display resolution for PF5 recordings |
Memory | 16MB internal + 4GB external |
Logger mode | |
Sampling | Combination of 5 readings/sec and 100/1202 readings/sec continuous sampling per channel depending on the parameter measured |
Recording time | Depends on selected readings and averaging time |
Memory | 16MB internal + 4GB external |
Monitor mode | |
Sampling | Combination of 5 readings/sec and 100/120 readings/sec continuous sampling per channel depending on the parameter measured |
Recording time | Up to 1 week with 10 min resoluto |
Memory | 16MB internal + 4GB external |
Limits | According EN50160 or customer definable |
Measurement method
Vrms, Arms | 10/12 cycle contiguous non overlapping intervals using 500/416 samples per cycle in accordance with IEC 61000-4-30 |
Vpeak, Apeak | Absolute highest sample value within 10/12 cycle interval with 40 μs sample resolution |
V Crest Factor | Measures ratio between the Vpeak and Vrms |
A Crest Factor | Measures ratio between the Apeak and Arms |
Hz | Measured every 10 sec in accordance with IEC61000-4-30 |
Vrms½, Arms½ | Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle. This technique is independent for each channel in accordance with IEC 61000-4-30. |
Harmonics | Calculated from 10/12-cycle gapless harmonic group measurements on Voltage and Amps according to IEC 61000-4-7 |
Watt | Selectable Total or Fundamental real power display Calculates average value of instantaneous power over 10/12 cycle period for each phase Total Active Power PT = P1 + P2 + P3 |